pH: -2...+16 pH
mV: ±2000 mV
Ion: 0.01 ng/l...100 g/l
Conductivity: 0...2000 mS/cm
Resistivity: 0...200 MΩ.cm
Salinity: 0...70.0
TDS: 0...100 g/l
Dissolved oxygen: 0...60 mg/l
0...600%
Air pressure: 600...1300 hPa
Temperature: -5...+105°C
Ion: C6030 only
One channel for all measurements!
CODE DESCRIPTION
C6010 pH/conductivity/DO meter + USB cable
C6030 pH/Ion/conductivity/DO meter + USB cable
C60x0P Meter kit for pH: meter + pH/ATC electrode SP10T + 2x50 ml bu f fers (pH 4 and 7) + 50 ml electrolyte (3M KCl) + carrying case
C60x0K Meter kit for conductivity: meter + conductivity/ATC electrode SK10T + 50 ml conductivity standard (0.01 M KCl) + carrying case
C60x0Z Meter kit for oxygen: meter + dissolved oxygen electrode SZ10T + carrying case
C60x0T Meter kit complete: meter + pH/ATC electrode SP10T + conductivity/ATC electrode SK10T + dissolved oxygen electrode SZ10T + 2x50 ml bu f fers (pH 4 and 7)
+ 50 ml electrolyte (3M KCl) + 50 ml conductivity standard (0.01 M KCl) + carrying case
C60x0X Meter kit without electrodes: meter + 2x50 ml bu f fers (pH 4 and 7) + 50 ml electrolyte (3M KCl) + 50 ml conductivity standard (0.01 M KCl) + carrying case
SH300 Flexible electrode holder (optional)
A4049 Car adaptor, 12 V (optional)
è Supplied with a mains adaptor (100...240 VAC, EU/US) + 4 NiMH batteries(add a UK-sign for UK plug versions, e.g.:C6030-UK)
C6010 •C6030 Multi-parameter analysers
pH
Multi-point (1...5) calibration for more linearity.
Selectable resolution from 0.001 pH to 0.1 pH.
Automatic calibration with any of eleven pre-program med and five
user specified pH buffers. Create your own buffer/temperature
tables!
Accepts pH electrodes with any zero point (Eo) between ±999 mV.
mV
Features mV calibration for accurate ORP mea su rements.
Selectable resolution from 0.1 mV to 1 mV.
Ion (C6030 only)
Direct concen tration measurement.
Multi-point (2...5) calibration and an additional blank correction for
measuring low concentrations.
Stores calibration curves for up to 9 different electrodes.
Conductivity
Multi-point (1...3) calibration for more linearity.
An electrode with a typical cell constant of 1 cm
-1
permits to measure from 0.01 µS/cm to 200 mS/cm in five ranges.
An electrode with a typical cell constant of 0.1 cm
-1
permits to
measure from 0.001 µS/cm to 20 mS/cm in five ranges.
An electrode with a typical cell constant of 10 cm
-1
permits to
measure from 0.1 µS/cm to 2000 mS/cm in five ranges.
Automatically se lects cor rect range and frequency.
Selectable reference temperature: 20° or 25°C.
Automatic calibration with any of three pre pro grammed and three
user specified standard solutions. Create your own standard/
temperature tables!
Allows to lock the initial conductivity range to avoid non-li near
titration curves.
Accurate low conductivity measurements by eliminating the capacitive component of the electrode and its cable (avoid the use of long
cables!).
Dissolved oxygen
Operates with a galvanic dissolved oxygen electrode requiring no
polarisation time and no zero calibration.
Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l (1%).
Manual salinity compensation 0-40.
Automatic air pressure compensation 600-1300 hPa.
Temperature
Reads temperatures with 0.1°C resolution.
Manual or automatic temperature compensation.
Calibrates temperature probe for quality measurements.
multiparameter water quality meter