Anda butuh alat laboratorium dan reagents microbiology, segera hubungi Perusahan kami" . PT. SUMBER ARUM ABADI adalah distributor atau subdistributor supplier importir resmi Indonesia yang bergerak dibidang alat Laboratorium dan Microbiology di Surabaya Jawa Timur Indonesia , Dengan Merek Sebagai berikut : acumedia from neogen corp USA, merck KGaA Germany, sigma aldrich USA, waters For HPLC Ireland, ridacount, copan italy, biooscientific, difco, atago, bd, bbl, memmert, hirayama, atago, thermo scientific, thermolyne, funke gerber germany, warring, hach usa, olympus, seedburo, all american, vwr, sibata, horiba, uetech, yellowline, wildco, takemura, ATCC gibson laboratories Inc., As-One, pyrex, brand, biohit, axygen scientific, AZ Taiwan, boeco germany, gast vacuum pump, optika italy Microscope, motic Microscope, interscience france, hettich, and balance Japan, Ohaus Balances and Scale USA, mettler toledo balance USA, presica balance taiwan, kern balances germany, eppendorf, testo, velp scientifica, KNF neuberger, nabertherm vaccuum Pumps Germany, advantec toyo kaisha Ltd. Japan, kett Science And Sensing USA, eppendorf jerman, hanna instrument, IKA, hanil centrifuge taiwan, kern balances germany, GFL water still USA, acumedia, biogen, seward, wildco, haws, seward uk, witega germany, microessential, yazumi, neofilm neogen usa, pobel water stills spain, parafilm m bemis company inc. usa, sanita-kun japan, spectrum instruments australia, analytik jena germany, funke gerber germany, organomation usa, gibertini italy, stat fax 4200 microplate reader, stat fax 4700 microwell reader, automated elisa analyzer iea, labomed in. usa, deltatrak usa, miccroessentiallab usa dll

Detail Elektroda Consort Bvba Belgium

Overview
Consort offrs a wide variety high quality electrochemical analytical sensors. Our pH, ORP (Oxidation-Reduction Potential),
Conductivity, Oxygen and Ion Selective Electrodes (ISEs) are designed for Laboratory, Industrial, Biotechnology and Medical
applications.
The most common electrodes are in our catalogue. We can supply variations depending on your needs: body style, submersible,
cable length, body length, connector type, ATC type,…
Most of our electrodes can be delivered from stock. ISE’s are never delivered from stock because of it’s limited shelf life. An ISE is
manufactured on demand and as such will guarantee an ideal shelf life combined with a low price.
About B, N, T, T3, T3S, X, Y
Our electrodes have diffrent options indicated with a suffi Here is an explanation of the diffrent suffis:
B 1m cable
1 BNC connection
N 1m cable
2 banana connections
T built-in ATC (Pt1000)
1m cable
1 BNC connection
2 banana connections for ATC
T3 built-in ATC (Pt1000)
3m cable
1 BNC connection
2 banana connections for ATC
T3S submersible electrode
built-in ATC (Pt1000)
3m cable
1 BNC connection
2 banana connections for ATC
X S7 screw connection (separate cable (SCxxB) needed)
Y S8 screw head for in-line use, screw connection (separate cable (SCxxB) needed)
Tips and tricks
While calibrating or measuring, all solutions should be stirred gently to ensure the electrode gives a true representation of the beaker
contents.
Calibration solutions with values near the expected sample value should be chosen. Only fresh calibration solutions should be used.
Changing all solutions daily is a good practice. All solutions should be maintained at equal temperature.
Rinse the electrode twice between measurements: fist thoroughly in distilled water and then with a small amount of the next sample
to be measured. Allow the electrodes suffient time to stabilise while calibrating or measuring. A stability indicator on all of our meters
prompts the user when readings should be taken.

Code Body Junction Sealed pH °C size
SP10B
SP10T
SP10T3S
General Epoxy Single yes 0…14 0…80 110xØ12
SP11B
SP11T
SP11X
SP11Y
Rugged
Tuff-Tip Epoxy Double yes 0…14 0…100 110xØ12
SP20B
SP20T General Glass Single yes 0…14 0…100 110xØ12
SP21B
SP21T
SP21T3
SP21X
General Glass Single no 0…14 0…100 110xØ12
SP22X
SP22Y
High
Temp. Glass Double yes 0…14 5…110 110xØ12
SP24B
SP24T
SP24X
Spear Tip Ultem
Glass Double yes 0…14 0…80 25xØ5
SP26X Sleeve
Junction Glass Double no 0…14 0…100 110xØ12
SP27X Flat
Surface Epoxy Single yes 0…14 0…80 110xØ12
SP28X Micro
Electrode Glass Single no 0…14 0…80 130xØ4
SP29X Test Tube Glass Single no 0…14 0…100 250xØ8
SP9xY
Sterilisable
max 10
bar
Glass Double yes 0…13 -5…135
SP91Y: 110xØ12 mm SP92Y: 120xØ12 mm SP93Y: 130xØ12 mm
SP94Y: 160xØ12 mm SP95Y: 210xØ12 mm SP97Y: 310xØ12 mm
SP98Y: 360xØ12 mm
add -KIT to order an electrode with 50ml pH4 and pH7 + 50ml 3M KCl
pH electrodes
Code Body °C size
SP04X Titration glass double platinum 0…100 110xØ12
SP35B pH/ORP combi Glass
sealed
0…12 pH
0…±2000 mV
single junction
0…100 110xØ12
Special electrodes

Glassless pH electrodes SP40
Our NEW Liquid pH or LpH sensor is specially designed so that there is no glass in contact with the
solution being measured. Conventional glass pH electrodes are quickly etched and destroyed by HF
and as a result, current glass pH electrodes for HF applications use an extra thick membrane causing
slow sluggish response time. This is not the case with the SP40!
SP40 is an exact replacement for conventional glass pH electrodes. The SP40 is available in
Laboratory 12mm design with double junction reference for extended probe life.
Specifiations
pH Range 2 to 10
Temperature Range 0 to 40°C
Reproducibility +/- 2 %
Zero Potential (Eo) 7.00 pH
Slope (Span) 4 to 10 pH >93% of Scale
Offet (Zero) at 7pH 0 mV +/- 30 mV
Membrane Resistance <100 MΩ
Max Pressure 3 bar
Wetted Parts Kynar®, Viton®, PVC, and Epoxy
Code Description Junction pH °C size
SP40X S7 LpH sensor Double 2…10 0…40 110xØ12
SP40Y S8 LpH sensor Double 2…10 0…40 110xØ12

Ion selective electrodes Supplied with 1 m of cable and BNC plug
Polymer electrodes consist of various ion-exchange
materials in an inert matrix such as PVC, polythene or
silicone rubber.
Solid state electrodes utilise relatively insoluble
inorganic salts in a membrane.
Glass membrane electrodes are formed by the doping
of the silicon dioxide glass matrix with various chemicals.
Two versions available:
• Sealed (ISE20B…ISE37B)
• Refilable with replaceable membrane (ISE60B…ISE77B)
Gas sensing electrodes are available for the measurement of ammonia, carbon dioxides and nitrogen oxides. These electrodes have a
gas permeable membrane and an internal filing solution.
One versions available:
• Flat replaceable membrane (ISE50B…ISE52B)
All models are combination electrodes and have an epoxy body.
Dimensions: 110xØ12 mm
MODEL ION SENSOR RANGE (M) RANGE (ppm) °C INTERFERENCES pH ELECTROLYTE
ISE20B
ISE60B
Ammonium
NH
4
+
polymer 5.10-6 – 100 0.1 – 18000 0 – 50 K+ 4 – 10 NaCl
ISE21B
ISE61B
Bromide
Br
solid state 5.10-6 – 100 0.4 – 79900 0 – 50 I -, CN -, S2-, high levels
of Cl- and NH
3
2 – 14 KNO
3
ISE22B
ISE62B
Cadmium
Cd2+
solid state 10-7 – 10-1 0.01 – 11200 0 – 50 Cu2+, Hg2+, Ag+, high levels
of Fe2+ and Pb2+
2 – 12 KNO
3
ISE23B
ISE63B
Calcium
Ca2+
polymer 5.10-6 – 100 0.2 – 40000 0 – 50 Pb2+, Hg2+, Cu2+, Ni2+ 3 – 10 KCl
ISE24B
ISE64B
Chloride
Cl
solid state 5.10-5 – 100 1.8 – 35500 0 – 50 I -, Br-, CN -, S2- 1 – 12 KNO
3
ISE25B
ISE65B
Copper
Cu2+
solid state 10-8 – 10-1 0.00064 – 6350 0 – 50 Hg2+, Ag+, high levels of
Cl-, Br-, Fe2+ and Cd2+
2 – 12 KNO
3
ISE26B
ISE66B
Cyanide
CN
solid state 5.10-6 – 10-2 0.13 – 260 0 – 50 Cl-, Br-, I -, S2- 11 – 13 KNO
3
ISE27B
ISE67B
Fluoride
F
solid state 10-6 – sat. 0.02 – sat. 0 – 50 OH- 5 – 8 KCl
ISE28B
ISE68B
Fluoroborate
BF
4

polymer 7.10-6 – 100 0.1 – 10800 0 – 50 I -, ClO4-, CN – 2.5 – 11 (NH4)2SO4
ISE29B
ISE69B
Iodide
I
solid state 5.10-8 – 100 0.006 – 127000 0 – 50 S2-, CN -, Cl-, BrS2O3-2, NH30 – 14 KNO3ISE30BISE70BLeadPb2+solid state 10-6 – 10-1 0.2 – 20700 0 – 50 Hg2+, Ag+, Cu2+,high levelsof Fe2+ and Cd2+3 – 8 KNO3ISE31BISE71BNitrateNO3-polymer 7.10-6 – 100 0.5 – 62000 0 – 50 I -, ClO4-, CN -, BF4- 2.5 – 11 (NH4)2SO4ISE32BISE72BPerchlorateClO4-polymer 7.10-6 – 100 0.7 – 99500 0 – 50 – 2.5 – 11 (NH4)2SO4ISE33BISE73BPotassiumK+polymer 10-6 – 100 0.04 – 39000 0 – 50 Cs+, NH4+ 2 – 12 NaClISE34BISE74BSilver/SulphideAg+/S2-solid state 10-7 – 100 0.01 – 1079000.003 – 320000 – 50 Hg+, Hg2+ 2 – 12 KNO3ISE35B SodiumNa+glass 10-6 – sat. 0.02 – sat. 0 – 50 H+, K+, Li+, Ag+, Cs+, Tl+ 5 – 12 NH4ClISE36BISE76BSurfactantX+/Xpolymer 10-5 – 5.10-2 1 – 12000 0 – 50 similar types of surfactants 2 – 12 KClISE37BISE77BWater hardnessCa2+/Mg2+polymer 10-5 – 100 0.4 – 4000 (Ca2+) 0 – 50 Cu2+, Zn2+, Ni2+, Fe2+ 5 – 10 KClISE50B AmmoniaNH3gas sensing 5.10-7 – 100 0.01 – 17000 0 – 50 volatile amines 11 – 13 NH4ClISE51B Carbon dioxideCO2/CO32-gas sensing 10-4 – 10-2 4.4 – 440 0 – 50 volatile week acids 4.8 – 5.2 NaHCO3ISE52B Nitrogen oxidesNOxgas sensing 5.10-6 – 5.10-3 0.2 – 220 0 – 50 SO2, HF, acetic acid 1.1 – 1.7 NaNO2